The reason why the self-limiting temperature electric heating cable does not heat up when it is energized
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-05-30
- Views:0
(Summary description)Self-limiting temperature heating cable is composed of conductive polymer, two parallel metal wires and insulating sheath. Its characteristic is that the conductive polymer has a high positive temperature coefficient and is connected in parallel with each other. It can automatically adjust the output power with the temperature change of the heated system, and automatically control the temperature range. When the temperature reaches a specific value, it will automatically turn off the power. When the temperature When the value is lower than a certain value, the power will be turned on automatically, and the operation is convenient. It is widely used in pipeline heat tracing, heat preservation, antifreeze, anticondensation, etc. in various industries.
The reason why the self-limiting temperature electric heating cable does not heat up when it is energized
(Summary description)Self-limiting temperature heating cable is composed of conductive polymer, two parallel metal wires and insulating sheath. Its characteristic is that the conductive polymer has a high positive temperature coefficient and is connected in parallel with each other. It can automatically adjust the output power with the temperature change of the heated system, and automatically control the temperature range. When the temperature reaches a specific value, it will automatically turn off the power. When the temperature When the value is lower than a certain value, the power will be turned on automatically, and the operation is convenient. It is widely used in pipeline heat tracing, heat preservation, antifreeze, anticondensation, etc. in various industries.
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-05-30
- Views:0
The self limiting electric heating strip is composed of a conductive polymer, two parallel metal wires, and an insulation protective layer. Its characteristic is that conductive polymers have a high positive temperature coefficient and are connected in parallel with each other. They can automatically adjust the output power and control the temperature range according to the temperature changes of the heated system. When the temperature reaches a specific value, the power will be automatically turned off. When the temperature drops below a specific value, the power will be automatically turned on, which is easy to operate and widely used in various industries such as pipeline heating, insulation, antifreeze, and anti-condensation.
If the electric heating strip does not generate heat after installation, there may be several possible reasons:
1. The electric tracing band is damaged, and the testing location is exactly where the electric tracing band is damaged. The parallel structure determines that there is still current in the tracing band, but the damaged part cannot generate heat and needs to be repaired.
2. If there is no power supply voltage or the power supply voltage is too low, check the bus voltage at the power input point of the heat tracing circuit and fix the fault here.
3. The tail end is not properly sealed, and the two wires at the tail end of the electric tracing cable must be separated. The tail end junction box should be sealed with 704 sealant to prevent water from entering and causing a short circuit.
4. Exceeding the usage length of the self limiting temperature electric heating strip, the usage length of the self limiting temperature electric heating strip cannot exceed 100 meters, otherwise it may cause faults such as overheating of the heating strip.
5. The insulation layer has not undergone waterproof treatment. In rainy and snowy days, the insulation layer is soaked in water, causing the electric heating strip to be in a low temperature or humid state for a long time. It is necessary to re install the waterproof layer along the entire insulation layer to ensure that the electric heating strip works in a dry state.
Scan the QR code to read on your phone
Related information
-
Product advantages of self-limiting temperature heating cable
Compared with steam (hot water), electric heat tracing has many advantages as follows: (1) The electric heat tracing device is simple, heats up evenly, and can be remotely controlled to realize automatic management. - How heating cables work 2023-04-25
- Prospects for heating cables 2023-04-25
- Installation of heating cables 2023-04-25
- What is a radiant floor heating system? 2023-04-25
- Warmly congratulate Anhui Huanrui Electric Heating Equipment Co., Ltd. on its website launch! 2023-04-25
Disclaimer:
1. The text descriptions used on this site are strictly in accordance with the provisions of the Advertising Law, and there are inevitably omissions. If any omissions are found, guidance is welcome, and we will correct them immediately.
2. Some of the pictures used on this site are collected from the Internet, and the copyright owner cannot be contacted. If you inadvertently infringe on the intellectual property rights of the copyright owner, please call and tell us, and this site will delete it immediately.
Service Hotline:
Address: East of Hucheng Road, Feidong Economic Development Zone, Hefei, Anhui
Electric Tracing Business Unit:
Electric Floor Heating Business Unit:
Marketing Service Department:
+86-13965109920 Mr. Li
Copyright ©2022 Anhui Huanrui Electric Heating Equipment Co., Ltd 皖ICP备08006463号 | Powered by www.300.cn | Tags | Business License